• Increase font size
  • Default font size
  • Decrease font size

Infrastructure

Print PDF

Elaboration and Processing of Advanced Materials

 

1. CNC machine for materials machining FADAL VMC 2216FX

Fadal

Characteristics:

  • PC system for positioning and control
  • High quality and high speed processing
  • Ferous and non-ferous metals, polymers, wood
  • Processing speed: 8.000 rpm, 20.32m/min
  • Positioning precision: 0.005mm
  • Execution precision: 0,01mm
  • Types of products: Prismatic pieces, 3D complex models, Dies, injection dies, Electro-erosion electrodes, Prototypes

 

2. Planetary mill Pulverisette 4,6 (1 or 2 recipients)

pulverisette5    PV4

Characteristics:

  • Variable rotation of the plate and of the recipient
  • Milling mode: by friction / by impact
  • Rotation: 0-400 rpm
  • Initial dimension, max: 10 mm
  • Final dimension (thin): < 1 µm
  • Capacity of the recipient: 2 x 225 ml
  • Milling environment: air, neutral, criogenic;
  • Monitoring of temperature and pressure

 

 3. Nanoparticle Analysis System NANOSIGHT LM10

nanosight

Characteristics:

  • Laser: class 1, 635nm CW, max power 20mW
  • Vizualization, measurement and grain distribution 10-800nm;
  • Analysis of any type of particle in any solvent
  • Aplications: metals, ceramics, cosmetics, pharmaceuticals
  • Measurement: Number of particles, Distribution in volume, Distribution on surface

 

4. 90 Plus Particle Size Analyzer BROOKHAVEN

brookhaven 

Characteristics:

  • Laser: 15mW solid laser
  • Accuracy: ±1 – 2 % with monodispersed probes;
  • Measurement time: 1-2 minutes
  • Range: 2 nm-3µm;
  • Aplications: chemical industry, cosmetics, pharmaceuticals

 

5. CSM Instruments Tribometer and Profilometer

Tribometer

Characteristics:

  • High resolution due to the design of the friction force sensor;
  • Simply to calibrate;
  • Calibrated tool for friction and wear;
  • Heating probe is added option (up to 1000 ºC);
  • Testing liquids, humidity control, controlled environment

 

 6. Injection Moulding Machine GOCERAM

Injection machine

Characteristics:

  • Cavity volume: 0.020-200 cm3
  • Speed of injection: 0.4 - 100 cm³/s;
  • Injection time: 0.6 sec - 60 min;
  • Active time: up to 360 cycles/hour;
  • Servo-motor as actuator for the piston movement

 

 7. Microwave heating installation MUEGGE

Microwave 

Characteristics:

  • Magnetron 0,4 kV, 2.45 GHz
  • Anodic voltage: 3,5 kV;
  • Max power: 2 kW constant, 4 kW pulsed
  • Impedance Acorder: 6 kW, 2.45 GHz type TRISTAN

 

8. Arc welding equipment (MMA, TIG, MIG/MAG)

weld1    weld2    weld3

Characteristics:

  • AIR LIQUIDE Filcord 260 MC (260A, d=0.8-1.0 mm);
  • AIR LIQUIDE PRESTO 165 PLUS (160A, 26,4V);
  • OERLIKON CITOLINE 1700 M (170A, d=0.8-1.0 mm);
  • OERLIKON SAXO TIG 160 AC/ DC (150A, 80V);

 

9. Resistance spot welding machines TECNA 4640, TECNA 7903

Tecna    Tecna1

Characteristics:

  • Nominal power at 50%: 16 kVA
  • Max power/current: 35 kVA/10 kA
  • Min/Max electrodes : 230 / 550 mm
  • Displacement: 8...44 mm

 

10. Nd-YAG Laser Machine LASAG

laser 

Characteristics:

  • Max power: 200 W
  • Frequency of pulse: 5 kHz
  • Processing precision : < 20 mm
  • Max thickness of base material: 2 mm

 

11. Stud welding machine TSW 1500

stud

Characteristics:

  • Diameter of the stud: 2.5-8.0 mm
  • Voltage input: 230 V c.a.
  • Max current: 5 A
  • Loading time: 1-3 s

 

12. Welding truck

welding truck

Characteristics:

  • Voltage input: 230 V c.a.
  • Max speed: 5.0 m/min
  • Vertical displacement of the welding head: 20 mm

 

13. Oxy-gas welding and cutting kit Messer-Griesheim

oxy-gas kit

Characteristics:

  • Full kit: 6 heads for welding and 1 head for cutting
  • Device for the mechanization of the cutting process;
  • Device for circular operation
  • Cleaning tools

 

 14. Bhutan soldering kit PROS KIT

bhutan kit

Characteristics:

  • 3 soldering heads
  • Buthan torch.;
  • Auxiliary tools for soldering
  • Lighter

 
 15. Micro-milling machines PROXXON MF70, MICROMOT 50-E

mm1   mm2

Characteristics:

  • Voltage input: 230 V c.a.;
  • Rotation: 0-2000 rot/min; 5000-20000 rot/min
  • Power: 100 W; 40W
  • Displacement table: 200 x 70 mm

 

 16. Furnaces for heat treatments and sintering processes

cuptor1    cuptor2    cuptor3

Characteristics:

  • Furnace L120 (resistive heating, max temperature: 1200oC);
  • Furnace Automatica (silicium carbide bars max temperature 1500oC);
  • Furnace KO II (super-kantal bars, max temperature 1500oC);
  • IR monitoring of temperature, digital controller of heating

 

 17. Soldering station PROS KIT 608-352

soldering 

Characteristics:

  • Digital regulation
  • Temperature : 165...400 ºC;
  • Power: 50 W
  • Interchangeable head

 

 

Testing, Examination, Analysis

 

1. Universal testing machine LBG

lbg

Characteristics:

  • Max force: 100 kN;
  • Tensile test, Bending test, Compression test
  • Resolution: 0.001 kN
  • Min/Max speed: 0.1-450 mm/min
  • PC command and record

 

 

2. Electro-hydraulic press OMC 164

omc

Characteristics:

  • Max force: 1000 kN;
  • Compression, Bending test
  • Voltage input: 400 V c.a.
  • Electro-hydraulic

 

3. Microscopes and stereo microscopes

m1    m2    m3

Characteristics:

  • MOTIC - stereo;
  • OPTECH - stereo
  • CETI – metallographic, CCD camera added, analysis software

 

4. Micro-Vickers hardness testing on PC

vickers

Characteristics:

  • Vickers Diamond Indenter
  • Magnitude: 10x, 40x;
  • Force: 10-1000 g
  • Microscope with analogic reading;
  • Automatic control of the force loading

 

5. Derivatograph MOM

derivatograph

Characteristics:

  • Max temperature:1500oC
  • Thermogravimetric analysis;
  • PC recording
  • Ultra-precised analytical balance

 

6. PH-meter HANNA Instruments

ph meter

Characteristics:

  • pH Measurement Range: -2 – 16, 2000-16000 mV, -9.9 – 120 oC
  • Resolution: 0.01;
  • Precision: 0.01
  • Automatic compensation;
  • Temperature sensor
  • PC connector RS 232, software

 

7. Systronic Messtechnik Multilyzer NG Gas detector and analyser

analizer1

Characteristics:

  • Sensors for O2, CO, NO, SO2
  • Pitot tube 500 mm;
  • Humidity sensor
  • Temperature sensor;
  • PC connector RS 232, software, recording measurements

 

8. Systronic Messtechnik Multilyzer NG thermo-hygrometer FT3

analizer2

Characteristics:

  • Range for temperature: 40-120oC
  • Range for humidity: 0%rF – 100%rF;
  • PC connector RS 232, software, recording measurements

 

 

Auxiliary Support Equipment

 

1. Power sources for electronics

aux1    aux2

Characteristics:

  • Mono- double sources
  • Continuous and alternative current;
  • Analog and digital
  • Continuous or stepping adjustment

 

 2. Measurment instruments for electric / non-electric parameters

1     2    3

4      6      5

Characteristics:

  • Digital Multimeters
  • Power-meter;
  • Digital RLC bridge
  • Sygnametrics data aquisition board;
  • IR temperature measurement digital instruments
  • Measurement instruments for mechanics
  • Digital balances

 

3. Metkon system for preparing the specimens for microscopic analysis

  11       12

1314

Characteristics:

  • Full system for cutting and preparation of specimens
  • Resine inserting;
  • Digital adjustments